|   | World's only "DUAL SPRING MECHANISM" | |
|   | Stronger Contact Pressure, Lower Contact Resistance ensure Longer Stability and Reliability | |
|   | Compact in size and Bigger contact capacity 8A 125V AC, 5A 250V AC (Resistive) | |
|   | Overheat, Overload protector forAC devices (EP2 series for DC devices) | |
| Specifications | Dimensions (mm) | Applications | ||||
| Operating Temp | 60`150 i5 stepj |  | Motor, Transformer | |||
| Solenoid | ||||||
| Tolerance | }5,}7,}10 | Lighting Fixture | ||||
| Differential | 40}15K(Standardj | Heating Applliance | ||||
| Breaking capacity | 8A 125V AC 6000 cycle(resistive) 5A 250V AC 10000 cycle(resistive) | Resister, Charger | ||||
| Projector | ||||||
| Safety Approval* *Contact us for approved conditions in detail. | ||||||
| Model | Agency | Standard | Category | Electrical Ratings | Max Temp | File No. | 
| 
        JP71 JP72 | UL | UL 2111 | Motor Protector | 125V  250V AC 0.373Kw | 150 | E52703 | 
| c-UL | CSA C22.2 No.77 | Motor Protector | 125V/250V AC 0.373Kw | 150 | E52703 | |
| EN(VDE) | EN IEC 60730-2-22 | Thermal Motor Protector | 250V AC | 150 | 114031 | |
| EN(VDE) | EN IEC 60730-2-9 | Thermal Cut-out | 5A(3.5A)/ 250V AC resistive (inductive) 10000 cycles | 150 | 40022558 | |
| EN(VDE) | EN60730-2-3 | Thermal Ballast Protector | 2A/ 250V AC (inductive) 10000 cycles | 150 | 40010418 | |
| CQC | GB/T 14536.10  | Thermostat (Non-fused bimetal type) | 8A/125V, 5A/250V AC 
       | 150 | CQC04002009087 CQC03002008317 | |