| Specifications | Dimensions (mm) | Applications | ||||
| Operating Temp | 60`140 i5 stepj |  | Overheat Protector | |||
| Fan Heaters | ||||||
| Tolerance | }5,}7,}10 | Hand Dryers | ||||
| Differential | 30}15K(Standardj | Blenders | ||||
| Breaking capacity | 25A 125V AC 6000 cycle(resistive) 13A 250V AC 6000 cycle(resistive) | |||||
| Safety Approval* *Contact us for approved conditions in detail. | ||||||
| Model | Agency | Standard | Category | Electrical Ratings | Max Temp | File No. | 
| 
        UB81
         | UL | UL873 | Regulating | 25A/125V AC (resistive) 6000 cycles | 140 | E50124 | 
| UL | UL873 | Regulating | 13A/250V AC (resistive) 6000 cycles | 140 | E50124 | |
| c-UL | CSA C22.2  No.24 | Appliance Control | 25A/125V AC (resistive) 6000 cycles | 140 | E50124 | |
| c-UL | CSA C22.2  No.24 | Appliance Control | 13A/250V AC (resistive) 6000 cycles | 140 | E50124 | |
| EN(VDE) | EN IEC 60730-2-9 | Thermal Cut-out | 16A(2A)/ 250V AC resistive(inductive)
 10000 cycles | 140 | 40019064 | |
| CQC | GB/T 14536.10  | Thermostat (Non-fused bimetal type) | 25A/125V, 13A/250V AC (resistive) 6000 cycles
       | 150 | CQC11002059930 CQC11002059934 | |